MIDAS Pro 1/2/2C AES Port configuration - 6th Port in red

This issue is usually because the show has been created on a Pro 3/6/9/X Console or incorrect offline editor.

The issue is that only five out of six AES50 Ports will configure correctly.

1. Go to Home/Preferences/General and reset restore “Restore Default Globals”
2. Click OK
3. Ensure that you reset the correct patching and I/O Set-up, and other default globals
4. Once complete please re-save relevant Show/Scenes

* See attached for further detail